Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

It is possible to customize the alert severities and their targets. For the configuration guide, see: Customizing Alert

...

Severities and Selective Alert Sending

General alerts:

Alert Name

Severity

Trap OID

Event IDResolved by

Free Memory Low

Fatal

1.3.6.1.4.1.39067.100.0.1

1Free Memory OK

Free Memory OK

Fatal

1.3.6.1.4.1.39067.100.0.2

2-

Disk Space Low

Fatal

1.3.6.1.4.1.39067.100.0.3

3Disk Space OK

Disk Space OK 

Fatal

1.3.6.1.4.1.39067.100.0.4

4-

Service Down

Fatal

1.3.6.1.4.1.39067.100.0.5

5Service Up

Service Up

Fatal

1.3.6.1.4.1.39067.100.0.6

6-

Recording Inactivity

Fatal

1.3.6.1.4.1.39067.100.0.7

7Recording Inactivity Over
Database Connection DownCritical1.3.6.1.4.1.39067.100.0.1010Database Connection Up
Database Connection UpCritical1.3.6.1.4.1.39067.100.0.1111-

Database Error

Critical1.3.6.1.4.1.39067.100.0.1212-
Prerequisite MissingFatal1.3.6.1.4.1.39067.100.0.1313-

Recording Inactivity Over

Fatal

1.3.6.1.4.1.39067.100.0.14

14-
Certificate is not accessibleFatal1.3.6.1.4.1.39067.100.0.1515-
Certificate expiresWarning1.3.6.1.4.1.39067.100.0.1616-
Certificate expiredCritical1.3.6.1.4.1.39067.100.0.1717-
Certificate not trustedCritical1.3.6.1.4.1.39067.100.0.1818-

Certificate revoked

Critical1.3.6.1.4.1.39067.100.0.1919-
Certificate key is not accessibleCritical1.3.6.1.4.1.39067.100.0.2020-
Configuration ErrorFatal1.3.6.1.4.1.39067.100.0.2121-
UndefinedCritical1.3.6.1.4.1.39067.100.0.999999-
Folder access problemError1.3.6.1.4.1.39067.999.10910Folder access problem resolved
Folder access problem resolvedNotification1.3.6.1.4.1.39067.999.11911-

...