PropertyDescription
oid_filter

A regex filter that has to match the last three numbers of the alert OID. For example:

"\.115\.0\.1" matches to the alert OID 1.3.6.1.4.1.39067.115.0.1

"\.115\.0\.." or "\.115\.0\.\d" matches to alert OIDs 1.3.6.1.4.1.39067.115.0.1-9

"\.115\.0\.\d{2}" matches to alert OIDs 1.3.6.1.4.1.39067.115.0.10-99

severity

Sets the new severity for the alert(s). If not specified, the default severity of the alert(s) will be used. Possible values:

  • 0 - Disables the alert(s)
  • 1 - Fatal
  • 2 - Critical
  • 3 - Error
  • 4 - Warning
  • 5 - Notification

disabled_targets

Specifies to which alert targets should not the alert be sent. If not specified, the alert(s) will be sent to all targets. Possible values:

  • snmp - The alert(s) will not be sent to the SNMP target
  • db - The alert(s) will not be inserted into the Verba database, so they won't be available in the Alert Management menu
  • mail - The alert(s) will not be sent to the email target
  • eventlog - The alert(s) will not be inserted into the Windows Event Log
  • all - Disables the alert(s)
  • none - The alert(s) will be sent to all targets

Multiple values can be provided, separated by a comma.

...